The Komori H-UV System is an innovative UV curing system that uses a UV lamp developed with Komori
know-how and high-sensitivity UV ink. With just one lamp mounted in the delivery, this system offers high print
quality and reliability as well as excellent economic and eco-friendly performance.
Advantages of UV Curing System

- Shorter Total Turnaround Time
- Job turnaround time is dramatically shorter than with conventional printing because
printed items are cured instantly by an in-line process. UV curing is extremely effective in
shortening the time from receipt of materials to delivery because finishing work such as
cutting, die cutting and folding can be performed immediately.

- Reduction of Stock Space
- Since there is no waiting for printed items to dry as required with conventional printing,
a large stock space for printed work is not required. The stock space necessary to
accommodate the increasing number of short runs of varied items can be reduced.

- Improved Quality due to Powderless Operation
- Since the entire printing process is powderless, the plant has none of the troubles
associated with the scattering of powder granules. The surface of printed items is smooth,
which makes surface processing in postpress very easy. Also, since the problems resulting
from supplementary printing by an on-demand press can be reduced, UV curing can
facilitate more orders in applications that require no adhesion of drying powder.
The elimination of the dry down phenomenon also makes it easier to check quality.
Advantages of H-UV System: Economical

Advantages of H-UV System: Eco-friendly

System Configuration Drawing (for GL40)

Press Configuration Drawings
List of Applicable Models
Lithrone S Series 26-, 29-, 32-, 40-and 44-inch presses
LS-26 LS-29 LS-26P LS-29P LS-32 LS-40 LS-40P LS-44
Lithrone G Series 40-inch presses
GL-40 GL-40P
Lithrone SX Series 29- and 40-inch presses
LSX-29 LSX-40 LSX-40RP
* Not applicable with Lithrone S SP Series, Enthrone Series, Spica Series and System Series web offset presses. * Sheet thickness and printing speed depend on press specifications.
Specifications
| Item |
H-UV System |
Conventional UV System |
| Control of lamps |
Ignition about 1 min Extinction about 3 min |
Ignition about 1 min
Extinction about 3 min |
| Substrate temperature |
Room temperature +4~5º C |
Approximately 40º C or more |
| Ancillaries |
Electric panel/Chiller/Blower for water/air cooling |
Electric panel/Chiller/Blower for water/air cooling |
| Ozone exhaust ducting |
Not required |
Required |
| Ozone |
None |
Yes |
| Lamp life *1 |
2,000 hours (120~160 W/cm)×1 lamp |
1,500 hours (160 W/cm)×4~5 lamps |
Power consumption per day *2
For Lithrone G40
For Lithrone G40P |
268.8 kW 447.3 kW |
1105.3 kW 1437.1 kW |
| Total life cost *3 |
1 |
3.6 |
* 1 Varies according to ignition conditions.
* 2 Calculated at 10 hours per day of operation and operating ratio of 40 percent, including chiller (standby time included).
* 3 Where H-UV System is 1
1.The values shown here represent measurements made by Komori under specific conditions and are not guaranteed.
2.Performance and values will vary according to specifications. Specified values may be changed for the purpose of product improvement
|